Oil Tank Services

Tank certifications, leak detection via soil
borings, under fill integrity tank testing and environmental profiling.
Underground and aboveground tank installations, replacements, removals and
closures. Scroll down for more info.

More
Photos
Residential Tank Replacement
Program:
- 275 gallon Roth Safety Tank Installations - ANCO is a stocking distributor of Roth's
double-walled corrosion-proof aboveground residential oil tank. The tank is
provided with a 10-year, $1M environmental liability warrantee. The tank is
lightweight and low-cost.
Another option is a single-walled tank, like the Highland Toughtank. See
photos below.
Roth's Double Walled
Tank |
Highland Toughtank |
Click on the photo
above to view Roth's informative brochure.*
|
Click on the photo
above to view
Highland's informative brochure.* |
| Capacity: |
165 gal. |
275 gal. |
400 gal. |
Capacity: |
230 gal. |
275 gal. |
330 gal. |
| Length: |
29" |
43" |
64" |
Length: |
60" |
60" |
72" |
| Width: |
28" |
28" |
30" |
Width: |
22.25" |
27.25" |
27.25" |
| Height without base: |
59" |
59" |
66" |
Height without base: |
44.25" |
44.25" |
44.25" |
*You
will need Adobe Reader to view these brochures. If you don't have Adobe Reader on your
computer, please CLICK HERE to download the latest version for free. |
|
|
|
|
|
|
|
|
- Up to 5 tanks can be easily interconnected.
- 100% financing, with 0% interest if paid
within one year. Tank removal and/or cleanup financing is also available.
- Eliminate underground tank concerns thus
facilitating smoother property transactions.
ANCO's
Tank Certification Program:
ANCO offers a comprehensive oil
tank inspection and testing program that provides
environmental liability assessment of underground
storage tank systems (USTs). Test methodology
includes collecting four bored soil samples from
approximately 0-6" deeper than the tank, then
screening them for Petroleum Hydrocarbons. One
sample is then sent to a certified laboratory for
quantitative analysis. This confirms the presence or
lack of contamination. Finally, we test the contents
of the tank for water. The dimensions, layout and
capacity of the tank are then presented in report format
along with certification of findings.
Our test methods are effective in
identifying soil contamination resulting from a
leaking UST, surface spill, or previously
removed leaking tank system. The tank does not have
to be filled with oil. Our test method is applicable
to active (in use) tank systems, previously
closed tank systems, and in conjunction with
in-place tank closures.
Certification language is clear
and definitive. Soil sample results are compared to
state standards and a conclusion is drawn as to
whether a discharge has occurred. In cases where
there is no evidence of a discharge, ANCO issues a "No
Evidence of Contamination" certificate.
Finally for active USTs returning
with "No Evidence of Contamination," tank insurance is readily available through an
affiliate fuel oil dealer, protecting the property
owner against future leaks.
Program Components:
- Magnetometric Detection and tank location services explore all leads
that point to the past or present existence of
an underground oil tank. Unknown piping,
sinkholes in the lawn, oily odor in the basement
or crawl space, or presence of copper piping are
all investigated.
- Percussion rods are
driven into the surrounding soil to verify
length, capacity, and direction of the tank.
- Hand Augered Samples are
collected from around an underground tank, and is a
more accurate method of evaluation liability
than volumetric or pressure testing. Soils are
continuously checked down to a 6'-7' depth for odor
and staining. This test method will reveal the
presence of soil contamination from a current
leaking tank, leaking piping, overspills, and
past leaks.
- Soil Samples collected
from 0-6" deeper than the tank via the hand
auger technique are sealed in Teflon-lidded
containers and stored in an ice chest. A sample
location map is generated at the time of the
sample collection. For active or inactive tanks,
water paste is used to detect the presence of
unwanted water in the tank
- Formal Analysis is
performed according to state guidelines using
accepted EPA methodology, providing quantitative
certifiable results for field test positive for
petroleum hydrocarbons.
- The Certified laboratory
Report quantifies the degree of
contamination and documents the evidence in a
report which is then incorporated into ANCO's
certification.
- No Evidence of Contamination
Certificate is issue with ANCO documenting
in clear language, certifiable proof that there
is no evidence of petroleum contamination in the
sample collected.
Tank Removal or Closure:
- ANCO has removed or closed over 12,000
tanks since 1981.
- Turn-key service is not reliant upon third
party subcontractor.
- Reusable oil is purchased.
- Tank (excavation) is filled with gravel.
- Site regraded upon completion - surface
restoration capabilities (i.e. concrete).
- If tank has leaked, up to 100% financing
through third party programs.
Back
to Our Services
|